Jlg 340AJ Service Manual Instrukcja Użytkownika Strona 272

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 271
SECTION 6 - JLG CONTROL SYSTEM
6-28 – JLG Lift – 3121259
Table 6-7. Machine Configuration Programing Information
Configuration Label/Digit Number Description
Default
Number
The machine configuration must be completed before any personality settings can be changed. Changing the personality settings first and then changing the model number of the
machine configuration will cause the personality settings to return to default.
MODEL NUMBER:
1
0
1
2
????: Visible only on a Non-Configured UGM
340AJ
NO MODEL
1
MARKET:
2
1
2
3
4
5
6
ANSI USA
ANSI EXPORT
CSA
CE
AUSTRALIA
JAPAN
1
ENGINE:
3
1
2
KUBOTA D1105132
DUAL FUEL ECM: GM/PSI 0.97L Duel Fuel (Tier 3)
1
FLYWHEEL TEETH:
4*
1 98 TEETH: 98 flywheel teeth. 1
* This menu item is not visible
GLOW PLUG:
5*
1
2
3
NO GLOW PLUGS: No glow plugs installed.
AIR INTAKE: Glow plugs installed in the air intake on the manifold.
IN-CYLINDER: Glow plugs installed in each cylinder.
3
* This menu item is not visible
STARTER LOCKOUT:
6*
1
2
DISABLED: Automatic pre-glow time determined by ambient air temperature; engine start can be
attempted at any time during pre-glow.
ENABLED: Automatic pre-glow time determined by ambient air temperature; engine start is NOT permitted
until pre-glow is finished.
1
* Th is me nu ite m i s vi sib le onl y if Engin e = Ku bo ta D1105
ENGINE SHUTDOWN:
7
1
2
DISABLED: No engine shutdown.
ENABLED: Shutdown engine when coolant temperature is greater than 110 deg. C or the oil pressure is less
than 8 PSI.
2
FUEL CUTOUT:
8*
1
2
ONE START: One start with limited run time when near Empty.
ENGINE STOP: No starting permitted when near Empty.
1
* Th is me nu ite m i s vi sib le onl y if Engin e = Ku bo ta D1105
Przeglądanie stron 271